 |  |  | PERF-O-GRIP 13-Hole, 24" Width | PRODUCT SELECTION/ DESIGN TABLES | MATERIAL GRADE | CHANNEL DEPTH | WEIGHT LB. / LIN. FT. | SPAN | | 3'-0" | 3'-6" | 4'-0" | 4'-6" | 5'-0" | 5'-6" | 6'-0" | 6'-6" | 7'-0" | 7'-6" | 8'-0" | 9'-0" | STEEL 13 GA. | 2 | 8.9 | U D C D | 486 .06 1395 .05 | 357 .09 1196 .06 | 273 .12 1046 .09 | 216 .15 930 .11 | 175 .18 837 .14 | 145 .22 761 .17 | 123 .26 697 .20 | 105 .31 644 .23 | 91 .36 598 .27 | 79 .41 558 .31 | 70 .47 540 .37 | 56 .60 504 .49 | 3 | 9.8 | U D C D | 876 .04 2528 .03 | 644 .06 2167 .04 | 493 .08 1896 .05 | 389 .10 1685 .07 | 315 .12 1517 .09 | 261 .15 1379 .10 | 219 .18 1264 .12 | 187 .21 1167 .15 | 161 .24 1083 .17 | 141 .28 1011 .19 | 124 .32 948 .22 | 99 .40 843 .30 | | ALLOWABLE LOADS AND DEFLECTIONS: U - UNIFORM LOAD (LB./FT.), C - CONCENTRATED LOAD (LB.), D - DEFLECTION (IN.). SPANS TO THE LEFT OF ANY HEAVY LINE PRODUCE A DEFLECTION OF 1/4" OR LESS UNDER A UNIFORM LOAD OF 100 LBS. PER SQUARE FOOT. FOR PERF-O GRIP PRODUCT WIDTHS GREATER THAN 12", USE OF GRATING SPLICE KIT IS RECOMMENDED TO MECHANICALLY JOIN BUTT ENDS OF LENGTH. | | |  | |  |  |